首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   25篇
  免费   0篇
化学   17篇
物理学   8篇
  2015年   1篇
  2013年   1篇
  2011年   3篇
  2010年   1篇
  2009年   1篇
  2007年   1篇
  2006年   7篇
  2005年   1篇
  2004年   4篇
  2003年   3篇
  2001年   1篇
  1997年   1篇
排序方式: 共有25条查询结果,搜索用时 15 毫秒
1.
The selective and simultaneous ion-exclusion chromatography (IEC) with UV-detection on a weakly acidic cation-exchange resin column in the H+ -form (TSKgel Super IC-A/C) was developed and applied for the simultaneous determination of phosphate and silicate ions as the water quality parameters required for optimizing the water-leaching process for ceramics glaze raw materials of natural origin including feldspar, woods-ash, and straw-ash. Phosphate and silicate ions in these water-leaching process water samples were separated selectively from the coexisting anions such as sulfate, chloride, nitrate and carbonate ions, based on the ion-exclusion separation mechanism. They were detected selectively and simultaneously by a postcolumn derivatization with molybdenum-yellow using the UV-detector. Under the optimized separation and detection conditions (eluent, 0-1 mM sulfuric acid; reactant, 10 mM sodium molybdate-25 mM sulfuric acid; detector, UV at 370 nm; temperature, 45 degrees C), the linearity of calibration was in the range 0.1 - 10 ppm for both phosphate and silicate ions, and the detection limits at S/N = 3 were 2.58 ppb for silicate ions and 4.75 ppb for phosphate ions. The effectiveness of this method was demonstrated in practical applications to the water-leaching process for some ceramics glaze raw materials.  相似文献   
2.
In this study, an aqueous solution consisting of benzoic acid with low background conductivity and beta-cyclodextrin (beta-CD) of hydrophilic nature and the inclusion effect to benzoic acid were used as eluent for the ion-exclusion chromatographic separation of aliphatic carboxylic acids with different pKa values and hydrophobicity on a polymethacrylate-based weakly acidic cation-exchange resin in the H+ form. With increasing concentration of beta-cyclodextrin in the eluent, the retention times of the carboxylic acids decreased due to the increased hydrophilicity of the polymethacrylate-based cation-exchange resin surface from the adsorption of OH groups of beta-cyclodextrin. Moreover, the eluent background conductivity decreased with increasing concentration of beta-cyclodextrin in 1 mM benzoic acid, which could result in higher sensitivity for conductimetric detection. The ion-exclusion chromatographic separation of carboxylic acids with high resolution and sensitivity was accomplished successfully by elution with a 1 mM benzoic acid-10 mM cyclodextrin solution without chemical suppression.  相似文献   
3.
A new ion chromatographic (IC) system has been established by using micelles of 3-(N,N-dimethylmyristylammonio)propanesulfonate (Zwittergent 3-14) loaded onto a reversed-phase packed column as the separation column with an electronic rotary switching valve packed-bed suppressor for conductometric detection of inorganic anions. An aqueous H3BO3-Na2B4O7 solution has been demonstrated to be the most desirable eluent for this IC system. The relationship between retention time and the concentration of the borate eluent was determined for a series of model anionic analytes and this relationship was found to be opposite to that exhibited in a conventional anion-exchange IC system. The rapid elution and complete separation of monovalent inorganic anions were obtained by initially using a high-concentration borate solution as the eluent for a short-period, and then switching to a lower-concentration borate eluent to complete the separation. Detection limits for nitrite, bromide, nitrate, and chlorate were 0.85, 0.88, 0.95 and 4.8 microM, respectively, when a 7.0 mM Na2B4O7 eluent was used. Moreover, the ability to directly detect these monovalent anions in samples containing high concentrations of sulfate and/or chloride ions provided a major advantage of this approach.  相似文献   
4.
5.
Mori M  Itabashi H  Ikedo M  Tanaka K 《Talanta》2006,70(1):174-177
An ion-exclusion chromatographic method for the direct UV detection of non-absorbing inorganic cations such as sodium (Na+), ammonium (NH4+) and hydrazine (N2H5+) ions was developed by connecting an anion-exchange column in the I-form after the separation column. For example, NH4+ is converted to a UV-absorbing molecule, NH4I, by the anion-exchange column in the I-form after the ion-exclusion separation on anion-exchange column in the OH-form with water eluent. As a result, the direct UV detection of Na+, NH4+ and N2H5+ could be successfully obtained as well as the well-resolved separation. The calibration graphs of the analyte cations detected with UV at 230 nm were linear in the range of 0.001-5.0 mM. The detection limits at S/N = 3 of the cations were below 0.1 μM. This method was applied to real water analysis, the determination of NH4+ in river and rain waters, or that of N2H5+ in boiler water, with the satisfactory results. This could be applied also to low- or non-absorbing anions such as fluoride or hydrogencarbonate ions by the combination of a weakly acidic cation-exchange resin in the H+-form as the separation column and the anion-exchange conversion column.  相似文献   
6.
The determination of seven aliphatic carboxylic acids, formic, acetic, propionic, isobutyric, n-butyric, isovaleric and n-valeric acids in anaerobic digestion process waters was examined using ion-exclusion chromatography with conductimetric detection. The analysis of these biologically important carboxylic acids is necessary as a measure for evaluating and controlling the process. The ion-exclusion chromatography system employed consisted of polymethacrylate-based weakly acidic cation-exchange resin columns (TSKgel OApak-A or TSKgel Super IC-A/C). weakly acidic eluent (benzoic acid), and conductimetric detection. Particle size and cation-exchange capacity were 5 microm and 0.1 meq./ml for TSKgel OApak-A and 3 microm and 0.2 meq./ml for TSKgel Super IC-A/C, respectively. A dilute eluent (1.0-2.0 mM) of benzoic acid was effective for the high resolution and highly conductimetric detection of the carboxylic acids. The good separation of isobutyric and n-butyric acids was performed using the TSKgel Super IC-A/C column (150 mm x 6.0 mm i.d. x 2). The simple and good chromatograms were obtained by the optimized ion-exclusion chromatography conditions for real samples from mesophilic anaerobic digestors, thus the aliphatic carboxylic acids were successfully determined without any interferences.  相似文献   
7.
Mori M  Tanaka K  Taoda H  Ikedo M  Itabashi H 《Talanta》2006,70(1):169-173
Ion-exclusion/adsorption chromatography of dimethylsulfoxide (DMSO) and its derivatives, i.e., methanesulfinic acid (MSI), methanesulfonic acid (MSA) and sulfuric acid (SA), was developed in order to clear the decomposition mechanism of DMSO on quality-test of TiO2-photocatalyst in water. The separation was achieved by the adsorption effect for DMSO and ion-exclusion effect for MSI, MSA and SA under optimum conditions, using a weakly acidic cation-exchange resin column with 20 mM succinic acid as the eluent. In this system, DMSO and MSI with UV at 195 nm and MSA and SA with conductivity detection were consecutively determined by single injection and single separation column. This method was used to monitor the artificial decomposition of DMSO induced by a photocatalyst. The concentration of DMSO by active oxygens (e.g., OH radical) generated from surface of photocatalyst was found to be decreased through the stoichiometric reaction in the order of MSI, MSA and SA.  相似文献   
8.
The quasi-one-dimensional (Q1D) cobalt oxides A(N + 2)Co(n + 1)O(3n + 3) (A = Ca, Sr, and Ba, n = 1 - infinity) were investigated by muon-spin spectroscopy under applied pressures of up to 1.1 GPa. The relationship between the onset Néel temperature T(on)(N) and the interchain distance (d(ic)), which increases monotonically with n, is well fitted by the formula T(N)/T(N,0) = (1 - d(ic)/d(ic,o)(beta), here for T(on)(N) approximately 100 K for Ca(3)Co(2)O(6) (n = 1) and approximately 15 for BaCoCoO(3) (n = infinity at ambient P. The T(on)(N) - d(ic) curve also predicts a large dependence of Y(N) for the compounds with n > or = 5, i.e., in the vicinity of , while the compounds show only a very small effect. Indeed, our high-pressure mu(+) results show that of BaCoO(3) is enhanced by with a slope of 2.2 K(Gpa), whereas no detectable changes by P for both Ca(3)Co(2)O(6) and Sr(4)Co(3)O(9) (n = 2). This clearly confirms the role of the 2D-antiferromagnetic interaction on T(on)(N) in the Q1D cobalt oxides.  相似文献   
9.
The simultaneous ion-exclusion/cation-exchange separation column packed with a polymethacrylate-based weakly acidic cation-exchange resin of 3 microm particle size was used to achieve the simultaneous high-speed separation of anions and cations (Cl(-), NO3(-), SO4(2-), Na(+), K(+), NH4(+), Ca(2+) and Mg(2+)) commonly found in environmental samples. The high-speed simultaneous separation is based on a combination of the ion-exclusion mechanism for the anions and the cation-exchange mechanism for cations. The complete separation of the anions and cations was achieved in 5 min by elution with 15 mM tartaric acid-2.5 mM 18-crown-6 at a flow-rate of 1.5 ml/min. Detection limits at S/N=3 ranged from 0.36 to 0.68 microM for anions and 0.63-0.99 microM for cations. This method has been applied to the simultaneous determination of anions and cations in several environmental waters with satisfactory results.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号